|
店鋪基本資料信息
|
品牌 | ABB | 產(chǎn)品ID | 1SFL451001R8900 |
產(chǎn)品型號 | A110-30-00-89 |
Q
EC000066 - Magnet contactor, AC-switching
EC000066 - Magnet contactor, AC-switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
39121529
4755 >> Contactors
box 1 piece
130 mm
265 mm
162 mm
2 kg
7320500187807
07172/D0 BV
SE-69487
CQC_2002010304008904
314005
2CMT2015-005436
DNV_E-12191
1SFC101001D0201
GL_99358-97HH
5309660-60
SE-9645071-2
LR_12-70027-E1
ELE060313XG/001
RMRS_12-03683-315
2CMT2015-005436
Main Circuit 600 V
(600 V AC) 140 A
(200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
3000 m
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 K40
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 K40
Following EU Directive 2011/65/EU
3
0
0
0
Main Circuit 1000 V
Main Circuit 50/60 Hz
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A
(690 V) 40 °C 160
(690 V) 55 °C 145
(690 V) 70 °C 130
(1000 V) 55 °C 30 A
(220 / 230 / 240 V) 55 °C 110
(380 / 400 V) 55 °C 110 A
(415 V) 55 °C 110 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(1000 V) 40 kW
(220 / 230 / 240 V) 30 kW
(380 / 400 V) 55 kW
(415 V) 59 kW
(440 V) 59 kW
(500 V) 59 kW
(690 V) 75 kW
8 x Ie AC-3
10 x Ie AC-3
gG Type Fuses 200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 175 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
AC-3 300 cycles per hour
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
(110 V) 2 Poles in Series, 40 °C 160 A
(220 V) 3 Poles in Series, 40 °C 160 A
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Main Circuit 8 kV
10 million
3600 cycles per hour
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
50 Hz 110 ... 115 V
60 Hz 115 ... 127 V
Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Between Coil De-energization and NC Contact Closing 7 ... 15 ms
Between Coil Energization and NO Contact Closing 10 ... 25 ms
Bar 30 mm²
Flexible with Cable End 2 x 6 ... 35 mm²
Rigid 2 x 6 ... 65 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
M8 hexagon socket screw with single connector
Cable Clamp
90 mm
123.5 mm
148 mm
1.8 kg